BQYJB - M30-A1 REFILL KIT CHEMICAL AGENT DETECTOR V

  • MSDS: BQYJB
  • Manufacturer: TRUETECH INC
  • Product Name: M30-A1 REFILL KIT CHEMICAL AGENT DETECTOR V
  • National Stock Number: 6665-00-909-3647
Product Identification

Product ID:M30-A1 REFILL KIT CHEMICAL AGENT DETECTOR V
MSDS Date:05/01/1990
FSC:6665
NIIN:00-909-3647
MSDS Number: BQYJB

Responsible Party
TRUETECH INC
680 ELTON AVE
RIVERHEAD, NY 11901-2555
US

Emergency Phone: 516-727-8600

Info Phone: 516-727-8600

Cage: 06421

Contractor
TRUETECH INC
RIVERHEAD, NY 11901-2555 US

Telephone: 516-727-8600

Cage: 06421

Ingredients

VM&P NAPHTHA (LIGROINE)

CAS: 8032-32-4

RTECS: OI6180000

OSHA PEL 300 PPM/400 STEL

ACGIH TLV: 300 PPM; 9293


2,6 DICHLOROINDOPHENYL ACETATE

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION MAY CAUSE
RESPIRATORY IRRITATION AND CENTRAL NERVOUS SYSTEM DEPRESSION.
CONTACT WITH SKIN AND EYES MAY CAUSE IRRITATION. NO EFFECTS STATED
FOR INGESTION. CHRONIC: NONE SPECIFIED BY M ANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALATION: COUGHING, WHEEZING, SNEEZING,
SHORTNESS OF BREATH, NARCOSIS, HEADACHE, NAUSEA, VOMITING,
ANESTHESIA, CONVULSIONS. EYES: REDNESS, TEARING, DISCOMFORT. SKIN:
REDNESS, DISCOMFORT. INGESTED: N ONE GIVEN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALED: MOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
BREATHING STOPPED. GET MEDICAL ATTENTION. EYES: FLUSH WITH LOTS OF
WATER FOR 15 MINUTES. GET MEDICAL ATTENTION. SKIN: WASH WITH SOAP
AND WATE R. INGESTION: DO NOT INDUCE VOMITING! GET IMMEDIATE
MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:23.0F,-5.0C
Extinguishing Media:FOAM, CARBON DIOXIDE, OR DRY CHEMICAL
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE CLOTHES.
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES OF CARBON MONOXIDE AND
CARBON DIOXIDE, NITROGEN OXIDES AND HYDROGEN CHLORIDE ON THERMAL
DECOMPOSITION.

Accidental Release

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. ABSORB WITH
INERT MATERIAL SUCH AS VERMICULITE AND PLACE IN A CLEAN, MARKED
CONTAINER FOR LATER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM
SOURCES OF IGNITION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR EMERGENCY OCCURS; USE NIOSH/MSHA APPROVED RESPIRATOR OR
SUPPLIED AIR RESPIRATOR OR SCBA, AS REQUIRED. USE IN ACCORDANCE
WITH 29 CFR 1910.134.
Ventilation:USE ADEQUATE EXPLOSION-PROOF MECHANICAL VENTILATION.
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

HCC:F2
Boiling Pt:>100.C, 212.F
Vapor Pres:48 MM HG
Spec Gravity:0.749 (WATER=1)
Evaporation Rate & Reference:3.9 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED LIQUID, ETHER-LIKE ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. HMIS:
CONTACT WITH STRONG OXIDIZING AGENTS, EXPOSURE TO SOURCES OF
IGNITION.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE,
NITROGEN OXIDES AND HYDROGEN CHLORIDE

Disposal

Waste Disposal Methods:INCINERATE IN A FURNACE IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.